NEOPOR® foam generator models MFG/MFG-A

MFG-AOptimum foam is achieved when adhering to the recommendations by NEOPOR®. The unit should be protected from direct sun and rain or dirt. When frost may be expected, the pump has to be drained of water when not in operation.

 

 

Technical datas and settings
Units MFG
(semi-automatic)
MFG-A
(fully-automatic)
Power supply
Volt 230 400
Cycles
Cycl. - 50
Power requirement
Watt 180 180
Rated Power
Amps 0.95 0.55
Measurements
mm 400 x 400 x 700
Weight (incl. Hoses)
kg 46 (42+4)
Weight of Transformer (110V)*
kg 10 10
Required Water-pressure
bar  (psi) - 4 (57)
Required volume of water
ltrs / min - 50
Required Air-pressure
bar  (psi) 6 (85)
Required Air-Volume
ltrs / min 500
Suction height of emulsion
mm 6.000 -
Water-hose (diameter)
inch 3/4
Air-supply hose  (diameter)
inch 1/2
Emulsion-suction hose (diameter)
inch 3/8
Foam-supply hose (diameter)
inch 2
Foam-output recommended
ltrs / sec 8
Recommended weight of foam
grams / ltr >80

Emulsion suction hose has to be filled with water when starting equipment